IBM System x3550 M4 Installation And Service Manual page 424

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

80070204-0a02xxxx • 80070208-0a01xxxx
80070204-0a02xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (PS 2 Fan
Fault)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702040a02xxxx or 0x800702040a02xxxx
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-supply fan.
2.
Replace power supply n. (n = power supply number)
80070208-0a01xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (PS 1 Therm
Fault)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702080a01xxxx or 0x800702080a01xxxx
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 4
Automatically notify Support: No
User response:
Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-supply fan.
1.
2.
Use the IBM Power Configurator utility to ensure current system power consumption is under limitation. For
more information and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/
powerconfig.html.
3.
Replace power supply n. (n = power supply number)
406
IBM System x3550 M4 Type 7914: Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents