IBM System x3550 M4 Installation And Service Manual page 530

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

806f060d-0407xxxx • 806f070c-2002xxxx
806f060d-0407xxxx
Array [ComputerSystemElementName] has failed. (Drive 7)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0407xxxx or 0x806f060d0407xxxx
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
Replace the RAID adapter.
4.
Replace the hard disk drive that is indicated by a lit status LED.
5.
806f070c-2001xxxx
Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2001xxxx or 0x806f070c2001xxxx
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
806f070c-2002xxxx
Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 2)
Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2002xxxx or 0x806f070c2002xxxx
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
512
IBM System x3550 M4 Type 7914: Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents