IBM System x3550 M4 Installation And Service Manual page 426

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

8007020f-2582xxxx • 80070219-0701xxxx
8007020f-2582xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (I/O
Resources)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020f2582xxxx or 0x8007020f2582xxxx
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following step to solve PCI I/O resource errors:
1.
Go to F1 Setup-> System Settings-> Device and I/O ports-> PCI 64 bit Resource and choose enable.
80070214-2201xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (TPM Lock)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702142201xxxx or 0x800702142201xxxx
Severity: Error
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID:
Automatically notify Support: No
User response:
Update the server firmware (see Recovering the server firmware).
1.
2.
If the problem persists, (trained technician only) replace the system board (see Removing the system board and
Installing the system board).
80070219-0701xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (SysBrd
Fault)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702190701xxxx or 0x800702190701xxxx
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check for an error LED on the system board.
2.
Check the system-event log.
408
IBM System x3550 M4 Type 7914: Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents