80010b01-2c01xxxx
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (Mezz Card Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b012c01xxxx or 0x80010b012c01xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-2d01xxxx
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (PCH Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b012d01xxxx or 0x80010b012d01xxxx
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80030006-2101xxxx
Sensor [SensorElementName] has deasserted. (Sig Verify Fail)
Explanation: This message is for the use case when an implementation has detected a Sensor has deasserted.
May also be shown as 800300062101xxxx or 0x800300062101xxxx
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0509
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.