80070202-0701Xxxx; 80070204-0A01Xxxx - IBM System x3550 M4 Installation And Service Manual

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

80070202-0701xxxx

Sensor [SensorElementName] has transitioned to critical from a less severe state. (SysBrd Vol
Fault)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702020701xxxx or 0x800702020701xxxx
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 1
Automatically notify Support: No
User response:
1.
Check the system-event log.
2.
Check for an error LED on the system board.
3.
Replace any failing device.
4.
Check for a server firmware update. Important: Some cluster solutions require specific code levels or coordinated
code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the
cluster solution before you update the code.
5.
(Trained technician only) Replace the system board.

80070204-0a01xxxx

Sensor [SensorElementName] has transitioned to critical from a less severe state. (PS 1 Fan
Fault)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702040a01xxxx or 0x800702040a01xxxx
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-supply fan.
2.
Replace power supply n. (n = power supply number)
80070202-0701xxxx • 80070204-0a01xxxx