AC power-supply LEDs:
Use this information to view AC power-supply LEDs.
The following minimum configuration is required for the DC LED on the power
supply to be lit:
v Power supply
v Power cord
Note: You must turn on the server for the DC LED on the power supply to be lit.
The following illustration shows the locations of the power-supply LEDs on the ac
power supply.
Figure 89. AC power-supply LEDs
The following table describes the problems that are indicated by various
combinations of the power-supply LEDs on an ac power supply and suggested
actions to correct the detected problems.
AC power-supply LEDs
AC
DC
On
On
Off
Off
Off
Off
Off
On
Off
On
142
IBM System x3550 M4 Type 7914: Installation and Service Guide
Error (!)
Description
Off
Normal operation.
Off
No ac power to the
server or a problem
with the ac power
source.
On
The power supply
has failed.
Off
The power supply
has failed.
On
The power supply
has failed.
Action
1. Check the ac power to the
server.
2. Make sure that the power
cord is connected to a
functioning power source.
3. Restart the server. If the error
remains, check the
power-supply LEDs.
4. If the problem remains,
replace the power-supply.
Replace the power supply.
Replace the power supply.
Replace the power supply.