Replacing The Serveraid Adapter Memory Module - IBM System x3550 M4 Installation And Service Manual

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

Replacing the ServeRAID adapter memory module

Use this information to replace the ServeRAID adapter memory module.
About this task
To install the ServeRAID adapter memory module, complete the following steps:
Procedure
Figure 158. ServeRAID memory module installation
10. Turn on the peripheral devices and the server.
260
IBM System x3550 M4 Type 7914: Installation and Service Guide
1. Read the safety information that begins on "Safety" on page vii and
"Installation guidelines" on page 33.
2. Turn off the server and peripheral devices and disconnect all power cords.
3. Remove the cover (see "Removing the cover" on page 36).
4. Remove the ServeRAID SAS/SATA controller (see "Removing a ServeRAID
SAS/SATA controller" on page 253).
5. Align the memory module with the connector on the ServeRAID adapter and
push it into the connector until it is firmly seated.
6. Reinstall the ServeRAID SAS/SATA controller (see "Replacing a ServeRAID
SAS/SATA controller" on page 254).
7. Reconnect the power cords and any cables that you removed.
8. Reinstall the cover (see "Replacing the cover" on page 209).
9. Slide the server into the rack.

Hide quick links: