13.3.1.8 Using the front management LAN connector

In order to use the front management LAN connector to access the iRMC S3
management controller, please proceed as follows:
Ê Ensure that Management LAN has been enabled in the BIOS:
Ê Enter the BIOS.
Ê Select the Server Mgmt menu.
Ê Under iRMC LAN Parameters Configuration, make sure that the
Management LAN setting is set to Enabled.
Ê Save your changes and exit the BIOS.
I
The front management LAN connector can be used to access the
iRMC S3 with either of the Management LAN Port settings enabled,
Management or Shared.
For detailed information on how to access the BIOS and modify
settings, refer to the "D2939 BIOS Setup Utility for PRIMERGY
RX300 S7" reference manual.
Ê Connect a client computer (e.g. notebook) to the front management LAN
connector.
I
It is not possible to simultaneously access the iRMC S3 from the front
and rear management LAN connectors. As soon as a LAN cable is
connected to the front management LAN connector, the iRMC S3
cannot be accessed via the rear management LAN connector.
After removing the LAN cable from the front management LAN
connector, the iRMC S3 will immediately become accessible via the
rear management LAN connector again.
RX300 S7
Upgrade and Maintenance Manual
77.
Front panel
435