13.4
Front cage
13.4.1 Replacing the front panel cage
Field Replaceable Units (FRU)
Average task duration: 10 minutes
13.4.1.1 Required tools
Preliminary and concluding steps: tool-less
●
Removing the front LAN connector:
●
– Phillips PH2 / (+) No. 2 screw driver
13.4.1.2 Preliminary steps
Perform the following procedures:
"Disabling BitLocker functionality" on page 85
Ê
"Opening the rack door" on page 64
Ê
"Locating the defective server" on page 56
Ê
"Shutting down the server" on page 65
Ê
"Disconnecting power cords" on page 66
Ê
"Extending the server out of the rack" on page 69
Ê
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page
"Removing the server cover" on page 72
Ê
"Removing the air duct" on page 73
Ê
"Removing the fan box" on page 183
Ê
RX300 S7
Upgrade and Maintenance Manual
Front panel
70.
445