Basic hardware procedures
Connecting the server to the direct current (optional DC hot-plug power
supply unit)
Figure 23: Connecting the server to the dc voltage
Ê Connect the power cord with the connector to the power supply unit of the
server (1).
Ê Attach the connector with the 2 screws (2).
Ê Connect the wire labeled "Ground" to an appropriate earth ground.
Ê Connect the other two wires of the power cable to the current bar on the rack
(see Technical Manual of the rack).
4.10

Switching on the server

V
CAUTION!
Before switching on the server, make sure the server cover is closed.
In order to comply with applicable EMC regulations (regulations on
electromagnetic compatibility) and satisfy cooling requirements, the
PRIMERGY RX300 S7 server must not run while the server cover is
removed.