Message
Error 064: Configuration changes have been limited to the API
interface
The API interface has restricted this interface from making
Description
configuration changes.
To make configuration changes from this interface, the API interface
Action
will need to update to allow this interface to make changes.
Message
Error 065: Cannot remove the last CLI user with Administrator
rights
There has to be at least one CLI user with Administrator rights.
Description
To remove this user, add another CLI Administrator and then delete
Action
this user.
Message
Error 068: The Switch IP Access Control List is Full
The list being activated has an invalid number of IP pairs.
Description
Make sure there is at least one IP address in the Access Control List.
Action
Message
Error 069: Duplicate Port Name
Two or more port names are identical.
Description
Port names must be unique. Make appropriate changes and
Action
re-submit. For more information, see
Message
Error 070: Invalid FRU Type
The requested FRU does not exist on this product.
Description
Consult the installation/service manual for this product to find
Action
appropriate FRU names.
Message
Error 071: FRU Not Installed
on page 2-27.