Advertisement

Output
Output Example

show.security.log

Syntax
Purpose
Parameters
Command Example
The fabric binding configuration data is displayed as a table that
includes the following properties:
Domain ID
The domain ID of the Fabric Binding
Membership List (FBML) member. Valid
domain IDs range from 1 to 239.
WWN
The world wide name (WWN) of the FBML
member in colon-delimited hexadecimal
notation.
Attachment
Indicates whether the FBML member is Local,
Status
Attached, or Unattached. For more information,
see
page 2-53.
The output from the show.security.fabricBinding command appears as
follows:
Domain 1
(20:30:40:50:60:70:8F:1A) (Local)
Domain 3
(00:11:22:33:44:55:66:77) (Unattached)
Domain 2
(88:99:AA:BB:CC:DD:EE:FF) (Attached)
Domain 14 (11:55:35:45:24:78:98:FA) (Attached)
log [clear]
This command shows the contents of the security log as maintained
in NV-RAM on the director or switch.
This command has one parameter:
This optional parameter causes all security log
clear
entries to be cleared.
Root> show security log
Fabric Binding Membership Terminology