Perf.preferredpath.setpath - McDATA 316095-B21 - StorageWorks Edge Switch 2/24 User Manual

Fw 08.01.00 mcdata e/os command line interface user manual (620-000134-740, november 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

perf.preferredPath.setPath

Syntax
Purpose
Parameters
Command Example
setPath destDomainID sourcePort exitPort
This command sets a preferred exit port, given the destination
domain ID and source port. An exit port can be set for each
combination of destination domain ID and source port.
NOTE: You cannot set a path where the Destination Domain ID is the same
as the domain ID of the switch.
This command has the following parameters:
destDomainId
Specifies the destination domain ID. Valid
domain IDs are in the range 1–31.
sourcePort
Specifies the number of the source port. Valid
port number values are:
0–11 for the Sphereon 4300
0–15 for the Sphereon 3016 and 3216
0-15 for the Sphereon 4400
0–23 for the Sphereon 45000–31 for the
Sphereon 3032 and 3232
0–31 for the ED-5000
0-31 for the Sphereon 4700
0–63 for the Intrepid 6064
0–127 and 132–143 for the Intrepid 6140
exitPort
Specifies the number of the desired exit port.
Valid port numbers values are:
0–11 for the Sphereon 4300
0–15 for the Sphereon 3016 and 3216
0-15 for the Sphereon 4400
0–23 for the Sphereon 45000–31 for the
Sphereon 3032 and 3232
0–31 for the ED-5000
0-31 for the Sphereon 4700
0–63 for the Intrepid 6064
0–127 and 132–143 for the Intrepid 6140
Root> perf preferredPath setPath 17 5 11
perf
CLI Commands
2-141
2

Advertisement

Table of Contents
loading

Table of Contents