show vlan association subnet

This command displays the VLAN associated with a specific configured IP-Address and net
mask. If no IP address and net mask are specified, the VLAN associations of all the
configured IP-subnets are displayed.
Format
show vlan association subnet [<ipaddr> <netmask>]
Mode
Privileged EXEC
Term
Definition
IP Subnet
The IP address assigned to each interface.
IP Mask
The subnet mask.
VLAN ID
There is a VLAN Identifier (VID) associated with each VLAN.

show vlan association mac

This command displays the VLAN associated with a specific configured MAC address. If no
MAC address is specified, the VLAN associations of all the configured MAC addresses are
displayed.
Format
show vlan association mac [<macaddr>]
Mode
Privileged EXEC
Term
Definition
MAC Address
A MAC address for which the switch has forwarding and or filtering information. The
format is 6 or 8 two-digit hexadecimal numbers that are separated by colons, for example
01:23:45:67:89:AB. In an IVL system the MAC address will be displayed as 8 bytes.
VLAN ID
There is a VLAN Identifier (VID) associated with each VLAN.

Double VLAN Commands

This section describes the commands you use to configure double VLAN (DVLAN). Double
VLAN tagging is a way to pass VLAN traffic from one customer domain to another through a
Metro Core in a simple and cost effective manner. The additional tag on the traffic helps
differentiate between customers in the MAN while preserving the VLAN identification of the
individual customers when they enter their own 802.1Q domain.