Vlan Cpu Set Command; Configuring Management Vlan Example; Figure 166 Vlan Cpu Set Command Example; Figure 167 Vlan Cpu Set Command Example - ZyXEL Communications IES-1248-51 User Manual

Adsl2+ ip dslam
Hide thumbs Also See for IES-1248-51:
Table of Contents

Advertisement

IES-1248-51/51A/53 User's Guide
This command displays the management VLAN (CPU). You can only use ports that are
members of this management VLAN in order to manage the IES-1248.
The following example sets VLAN ID 2 to be the CPU (management) VLAN.

Figure 166 VLAN CPU Set Command Example

ras> switch vlan cpu set 2

48.4.7 VLAN CPU Set Command

Syntax:
ras> switch vlan cpu set <vid>
where
<vid>
This command sets the management VLAN (CPU). You can only use ports that are members
of this management VLAN in order to manage the IES-1248.
The following example sets VLAN ID 2 to be the CPU (management) VLAN.

Figure 167 VLAN CPU Set Command Example

ras> switch vlan cpu set 2

48.4.8 Configuring Management VLAN Example

Note: After the following example configuration, you must connect to the first Ethernet
port through a VLAN aware device that is using the proper VLAN ID in order to
perform management.
By default, the IES-1248's ADSL ports are members of the management VLAN (VID 1). The
following procedure shows you how to configure a tagged VLAN that limits management
access to just one Ethernet port.
Note: Use the console port to configure the IES-1248 if you misconfigure the
management VLAN and lock yourself out.
1 Use the
for managing the IES-1248 (the "management" or "CPU" VLAN).

Figure 168 CPU VLAN Configuration and Activation Example

ras> switch vlan set 3 enet1:FT
318
The VLAN ID. Valid parameter range = [1 – 4094].
=
command to configure a VLAN ID (VID 3 in this example)
switch vlan set
Chapter 48 IEEE 802.1Q Tagged VLAN Commands

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ies-1248-51aIes-1248-53

Table of Contents