Installation - Omron trajexia CJ1W-MCH72 Operation Manual

Sysmac cj-series programmable controller
Hide thumbs Also See for trajexia CJ1W-MCH72:
Table of Contents

Advertisement

Installation

2-3
Installation
2-3-1
Hardware installation
!Caution
50
Obey the following precautions when you install the CJ1W-MCH72 in a PLC system:
Turn off the power supply to the PLC before the installation or connection of the
CJ1W-MCH72.
Use separate conduits or ducts for the I/O lines. This prevents noise from high-
tension lines or power lines.
Do not remove the label on top of the CJ1W-MCH72 during the installation and
wiring. The label makes sure that no foreign matter can enter the unit.
Remove the label on top of the CJ1W-MCH72 after the installation and wiring of the
unit. This makes sure that the unit cannot become overheated.
The CJ1W-MCH72 can be installed in any slot in a CJ-series CPU rack or in a
CJ-series expansion CPU rack. The CJ-series PLC supports up to 4
expansion CPU racks.
Up to 16 CPU bus units can be connected to one PLC. Also, the maximum
number of CJ1W-MCH72 units that can be connected to one PLC is 16.
PLC CPU rack
Expansion Backplane
Expansion Backplane
Expansion Backplane
10 Units max.
P
C
I
S
P
C
U
10 Units max.
P
I
S
I
10 Units max.
P
I
S
I
10 Units max.
P
I
S
I
PS: Power Supply Unit
CPU: CPU Unit
IC: I/O Control Unit
II: I/O Interface Unit
Expansion racks
Section 2-3
End cover
End cover
End cover
End cover

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents