Nortel 2350 Reference Manual page 283

Wlan-management software 2300 series
Hide thumbs Also See for 2350:
Table of Contents

Advertisement

Table 1: Authentication Attributes for Local Users (continued)
Attribute
service-type
session-timeout
(network access mode
only)
ssid
(network access mode
only)
start-date
Configuring Authentication, Authorization, and Accounting Parameters 283
Description
Type of access the user is
requesting.
Maximum number of
seconds for the user's
session.
SSID the user is allowed to
access after authentication.
Date and time at which the
user becomes eligible to
access the network.
WSS Software does not
authenticate the user unless
the attempt to access the
network occurs at or after
the specified date and time,
but before the end-date (if
specified).
Nortel WLAN—Management Software 2300 Series Reference Guide
Valid Value(s)
Access type, which can be one of the following:
2—Framed; for network user access
6—Administrative; for administrative access,
with authorization to access the enabled
(configuration) mode. The user must enter the
enable command and the correct enable
password to access the enabled mode.
7—NAS-Prompt; for administrative access to
the nonenabled mode only. In this mode, the
user can still enter the enable command and
the correct enable password to access the
enabled mode.
For administrative sessions, the WSS always
sends 6 (Administrative).
The RADIUS server can reply with one of the
values listed above.
If the service-type is not set on the RADIUS
server, administrative users receive NAS-Prompt
access, and network users receive Framed access.
Note: WSS Software will quietly accept Callback
Framed but you cannot select this access type in
WSS Software.
Number between 0 and 4,294,967,296 seconds
(approximately 136.2 years).
Name of the SSID you want the user to use. The
SSID must be configured in a service profile, and
the service profile must be used by a radio profile
assigned to Nortel radios in the Mobility Domain.
Date and time, in the following format:
YY/MM/DD-HH:MM
You can use start-date alone or with end-date.
You also can use start-date, end-date, or both in
conjunction with time-of-day.

Advertisement

Table of Contents
loading

This manual is also suitable for:

2360236123802382

Table of Contents