Nortel 2382 Configuration Manual

Wlan 2300 series security switch
Hide thumbs Also See for 2382:
Table of Contents

Advertisement

Nortel WLAN 2300 Series—Security
Switch Installation and Basic

Configuration Guide

*320656-E*
Part No. NN47250-301 (320656-E)
October 2007
4655 Great America Parkway
Santa Clara, CA 95054

Advertisement

Table of Contents
loading

Summary of Contents for Nortel 2382

  • Page 1: Configuration Guide

    Nortel WLAN 2300 Series—Security Switch Installation and Basic Configuration Guide *320656-E* Part No. NN47250-301 (320656-E) October 2007 4655 Great America Parkway Santa Clara, CA 95054...
  • Page 2: Fcc Statement (Usa Only)

    International Regulatory Statements of Conformity for the WSSs This is to certify that the Nortel WLAN Security Switch 2300 series switches are evaluated to the international regulatory standards for electromagnetic compliance (EMC) and safety and was found to have met the requirements for the following international standards: •...
  • Page 3: Ce Marking Statement (Europe Only)

    CE marking statement (Europe only) EN 55022 statements This is to certify that the Nortel WLAN Security Switch 2300 Series switches are shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC. Conformity is declared by the application of EN 55022 Class A (CISPR 22).
  • Page 4: Vcci Statement (Japan/Nippon Only)

    National Safety Statements of Compliance EN 60950 statement This is to certify that the Nortel WLAN Security Switch 2300 Series switches are in compliance with the requirements of EN 60950 in accordance with the Low Voltage Directive. Additional national differences for all European Union countries have been evaluated for compliance.
  • Page 5: Nom Statement (Mexico Only)

    100-240V AC, 50-60Hz, 2.0A Input: Model 2380 (Single power supply) 100-240V AC, 50-60Hz, 8/3.5A Model 2380 (with redundant supply) 100-240V AC, 50-60Hz, 8/3.5A Input: Model 2382 (with redundant supply) 100-240V AC, 50-60Hz, 1/0.5A Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide...
  • Page 6: Información Nom (Unicamente Para México)

    Modele 2380 (solo suministro de corriente) CA 100-240V 50-60 Hz 8-3,5A Modele 2380 (con suministro redundante) CA 100-240V 50-60 Hz 8-3,5A Entrada: Modele 2382 (con suministro redundante) CA 100-240V 50-60 Hz, 1-0,5A Denan statement (Japan/Nippon only) NN47250-301 (320656-E Version 02.01)
  • Page 7: Table Of Contents

    2360, 2361, 2380 and 2382 LEDs ........
  • Page 8 Powering on a 2360/2361, 2380 or 2382 ........
  • Page 9 Index ............81 Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide...
  • Page 10 10 Contents NN47250-301 (320656-E Version 02.01)
  • Page 11: How To Get Help

    To access some Nortel Technical Solutions Centers, you can use an Express Routing Code (ERC) to quickly route your call to a specialist in your Nortel product or service. To locate the ERC for your product or service, go to: http://www.nortel.com/erc...
  • Page 12 12 How to get help NN47250-301 (320656-E Version 02.01)
  • Page 13: Introducing The Nortel Wlan 2300 Series System

    Nortel WLAN 2300 System ........
  • Page 14: Documentation

    WLAN with the WLAN Management Software tool suite. Read this guide to learn how to plan wireless services, how to configure and deploy Nortel equipment to provide those services, and how to optimize and manage your WLAN.
  • Page 15: Safety And Advisory Notices

    Radiation. This situation or condition can cause injury due to improper handling of fiber-optic equipment. Note. This information is of special interest. Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide Translations of Important Messages section of this installation guide.
  • Page 16: Text And Syntax Conventions

    Text and syntax conventions Nortel manuals use the following text and syntax conventions: Convention Monospace text Bold text Italic text Menu Name > Command [ ] (square brackets) { } (curly brackets) | (vertical bar) NN47250-301 (320656-E Version 02.01) Sets off command syntax or sample commands and system responses.
  • Page 17: Wss Overview

    APs ..............30 A Nortel WLAN—Security Switch (WSS) provides mobility and authentication, authorization, and accounting (AAA) services for wireless or wired users. A WSS also controls the operation of Nortel Access Points, which control and manage IEEE 802.11 operation over the air.
  • Page 18: Wss Model Numbers

    1000BASE-TX copper interface and a Gigabit interface converter (GBIC) slot for insertion of a 1000BASE-SX or 1000BASE-LX fiber-optic interface. 2382 Two gigabit Ethernet ports. Each port has a miniature Gigabit interface converter (mini-GBIC) slot for insertion of a small form-factor pluggable (SFP) 1000BASE-SX or 1000BASE-LX fiber-optic interface.
  • Page 19: Hardware Features

    Serial console port Nortel WSS 2360/2361 switch A WSS 2360/2361 switch is one (RU) high and also can be installed in a standard 48.26-cm (19-inch) equipment rack or on a tabletop. Figure 2 Figure 2. Nortel WSS 2360 Switch—Front View 25.6 cm...
  • Page 20 WSS 2360 Switch—Front Panel Control Features Power supply Power supply LED The rear of the switch contains a label with the serial ID, MAC address, and other identifying information. NN47250-301 (320656-E Version 02.01) Serial console port 10/100 Ethernet 10/100 and AP...
  • Page 21: Nortel Wss 2380 Switch

    Power supply inlet serial number Like the other switch models, the rear of the WSS 2380 switch contains a label with the serial ID, MAC address, and other identifying information. Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide...
  • Page 22: Nortel Wss 2382 Switch

    Nortel WSS 2382 switch A WSS 2382 switch is one RU high and can be installed in a standard 48.26-cm (19-inch) equipment rack or on a tabletop. Figure 1 shows a front view of a WSS 2382 switch. Figure 5.
  • Page 23: Management Features

    Quick Start to reconfigure the switch. • Status LEDs—The Ethernet ports and power supplies on all switch models have LEDs that indicate their status. The management CPU on a 2380 and 2382 also have an LED. (For details, see page 24.) •...
  • Page 24: Status Leds

    The 2380 and 2382 provide high-bandwidth centralized control of many indirectly connected APs. The 2380 does not have 10/100 Ethernet ports and does not provide PoE. The 2382 has one 10/100 Ethernet port (port 3), but this port is intended for management purposes only, and does not provide PoE.
  • Page 25: Wss 2350 Leds

    Table 2: WSS Status LEDs—2360, 2361, 2380 and 2382 (continued) Appearance Power supply status Solid green Solid amber Unlit Gigabit fiber link Solid green activity (2380 and 2382 only) Blinking green (2380 and 2382) Gigabit copper link Solid green activity...
  • Page 26 10-Mbps link is operational. Traffic is active on the 100-Mbps link. Traffic is active on the 10-Mbps link. The switch is booting and is loading its configuration file. This LED state lasts for three seconds. The switch is booting but the factory reset switch is being pressed.
  • Page 27 Solid green Alternating green and amber Solid amber Blinking amber Unlit Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide Meaning For an AP’s active link, with PoE enabled, all the following are true: • AP has booted. •...
  • Page 28: Software Features

    • WLAN Management Software management application—WLAN Management Software is an extensive GUI application for planning, configuring, deploying, and managing a Nortel network and its users. WLAN Management Software uses Secure Sockets Layer protocol (SSL) to interact with WSS Software. •...
  • Page 29: Authentication, Authorization, And Accounting

    AP roaming—You can configure the WSS to allow users to roam from one AP to another on the same WSS. • Mobility Domain™ roaming—You also can configure a group of WSSs to allow users to roam from one switch to another. Regardless of the wired subnet connections, each user maintains the same IP address and session across the network.
  • Page 30: And Series 2332 Aps

    External antenna selector guides for AP-2330, AP-2330A, AP-2330B and Series 2332 APs Table 4: External Antenna Selector Guide for the AP-2330/AP-2330A/AP-2330B and Series 2332 APs for indoor operation Nortel Model Cushcraft Number S2403BHN36RSM DR4000072E6 (Discontinued) S2403BPXN36RSM DR4000088E6 (Replaces DR4000072E6) S2406PN36RSM...
  • Page 31 SQ5153WPN36RSM DR4000069E6 S5153WBPN36RSM DR4000070E6 S51514WPN36RSM DR4000071E6 Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide 24113 WLAN Directional Patch Panel Array Antenna with an average gain of 11 dBi, 3-foot cable with a Reverse SMA connector and either a tilt, wall or pole mounting capability. Antenna is rugged, easy to install and provides a very symmetrical and uniform 120 degree H-plane and 14 degree E-plane pattern.
  • Page 32 Table 4: External Antenna Selector Guide for the AP-2330/AP-2330A/AP-2330B and Series 2332 APs for indoor operation S4901790PN36RS DR4000090E6 SR49120DAN36RS DR4000091E6 Nortel Model Cushcraft Number S24493DSN36RSM DR4000078E6 Note. Outdoor operation is NOT supported by the Series 2332 access points at this time.
  • Page 33 Outdoor Operation Nortel Model Cushcraft Number S2403BPXN36RSM DR4000088E6 Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide Model WLAN AP-2330A and AP-2330B 2.4 GHz Antennas String WLAN Collinear Omni-directional Dipole Antenna that con- tains two collocated elements with an average gain of 4.9 dBi and a 3-foot cable with a Reverse SMA connector.
  • Page 34 S2409PN36RSM DR4000076E6 NN47250-301 (320656-E Version 02.01) 24493- The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the OUT-10 addition of the 10-foot plenum rated cable, the lightning protec- tion circuitry and the 10-foot outdoor rated extension cable. 24493- The "25"...
  • Page 35 PC2415NA36RSM DR4000077E6 Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide 24883- The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the OUT-10 addition of the 10-foot plenum rated cable, the lightning protec- tion circuitry and the 10-foot outdoor rated extension cable.
  • Page 36 S241290PN36RSM DR4000086E6 NN47250-301 (320656-E Version 02.01) 24143- The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the OUT-10 addition of the 10-foot plenum rated cable, the lightning protec- tion circuitry and the 10-foot outdoor rated extension cable. 24143- The "25"...
  • Page 37 SR24120DN36RSM DR4000087E6 Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide 24123- The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the OUT-10 addition of the 10-foot plenum rated cable, the lightning protec- tion circuitry and the 10-foot outdoor rated extension cable.
  • Page 38 Nortel Model Cushcraft Number S5153WBPN36RSM DR4000070E6 NN47250-301 (320656-E Version 02.01) 24113- The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the OUT-10 addition of the 10-foot plenum rated cable, the lightning protec- tion circuitry and the 10-foot outdoor rated extension cable.
  • Page 39 S51514WPN36RSM DR4000071E6 Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide 5643-OUT Output power is compensated for the addition of lightning pro- tection circuitry and the 10-foot plenum rated cable. 5643- The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable.
  • Page 40 NN47250-301 (320656-E Version 02.01) 5133-OUT Output power is compensated for the addition of lightning pro- tection circuitry and the 10-foot plenum rated cable. 5133- The "10" refers to the addition of the 10-foot outdoor-rated LMR-240 extension cable. Output power is compensated for the OUT-10 addition of the 10-foot plenum rated cable, the lightning protec- tion circuitry and the 10-foot outdoor rated extension cable.
  • Page 41: Installing And Connecting A Wss

    Installing a power supply in a 2380 switch ....... . .
  • Page 42 Open the carton and carefully remove the contents, if you have not already done so. Place the packing materials back in the carton and save the carton. Verify that you received each item in the previous list. If any item is missing or damaged, contact Nortel. NN47250-301 (320656-E Version 02.01) WSS with...
  • Page 43: Installation Requirements And Recommendations

    2380 switch fans and air inlets are located on the sides of the switch. 2360/2361 and 2382 switch fans are located in the rear of the switch and air inlets are located on the sides and front of these switches. In the 2380 switches, separate power supply fans are located on the front.
  • Page 44: Cable Requirements

    Cable Requirements Warning! The gigabit Ethernet fiber-optic interfaces use Class 1 lasers. To reduce the risk of eye injury, do not stare into the interface or otherwise direct the laser beam into your eye. To avoid installation problems, use the proper cables. Serial console cable The serial console port has a female DB-9 connector and supports the EIA-232D signaling standard.
  • Page 45: Network Cables

    AP, a router, or an end station such as a PC, printer, or server, use a straight-through cable. For direct connection to another switch, use a crossover cable. (The 10/100 Ethernet ports on the 2360 switch provides automatic MDI/MDX, which automatically crosses over the send and receive signals if required.)
  • Page 46: Ap Cable Requirement

    For example, make sure the switch is level in the equipment rack, is evenly fastened by screws on either side, and does not have a heavy object resting on one side of the switch.
  • Page 47: Installing A Wss

    Installing a WSS You can mount a 2360/2361, 2380 or 2382 switch in a standard 48.26-cm (19-inch) equipment rack or on a tabletop. Each WSS is shipped with two brackets for rack mounting and four adhesive rubber feet for tabletop mounting. The 2380 mounting brackets support either front or center mounting.
  • Page 48: Equipment Rack Installation

    Equipment rack installation You can install a 2380 switch into a front-mount or center-mount equipment rack. You can install a 2360/2361 or 2382 switch into a front-mount equipment rack. • Figure 8 shows how to install a 2380 switch into a front-mount equipment rack. (Installation of a 2360/2361 or 2382 is similar.)
  • Page 49 If you accidentally drop the WSS, you can be injured and the switch can be damaged. Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide n s o R s t n so R st Nortel recommends that you ask someone to assist you with the...
  • Page 50: Tabletop Installation

    Use the following procedures to install a second power supply or replace a failed power supply. (You cannot insert or remove power supplies in a 2360 and 2382 switch.) Note. To attach the power supply to a 2350, see NN47250-301 (320656-E Version 02.01)
  • Page 51: Installing A New Power Supply

    Inserting a Power Supply in a 2380 Tighten the thumbscrew using a #2 Phillips-head screwdriver. Go to “Powering on a WSS” on page Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide Figure 10, pushing gently but firmly until the...
  • Page 52: Replacing A Power Supply

    Figure 11. Removing a Power Supply from a 2380 Switch Place your other hand under the supply to support it and remove the supply the rest of the way out of the slot.
  • Page 53: Powering On A Wss

    PSE can be a dedicated PoE injector or even another networking switch such as the WSS that is capable of supplying PoE. To completely power off a 2350 or 2360/2361 or 2382, unplug the power cord, then unplug all Ethernet cables that are connected to other PoE devices.
  • Page 54: Powering On A 2350

    The procedure is the same for the 2350, 2360, 2361, 2380 or 2382 switch. Refer to this figure as you perform the procedure. (For cable requirements, see console cable” on page 44.)
  • Page 55: Troubleshooting A Serial Management Connection

    COM2 or another port. If none of the previous steps results in a management connection, use another serial cable. Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide “Troubleshooting a serial management Nortel WLAN 2300 System Software Quick Start Guide Nortel WLAN 2300 System Software connection”.
  • Page 56: Connecting To The Network

    • For connection to a router or to an end station such as a PC, printer, or server, use a straight-through cable. NN47250-301 (320656-E Version 02.01) Ethernet port Ethernet cable AP, switch, server (Cat 5 cable) or other device Figure...
  • Page 57 For connection to another switch, use a crossover cable. (For cable requirements, see cables” on page 45.) Note. The 10/100 Ethernet ports on the 2350, 2360/2361and 2382 switches provide automatic MDI/MDX. If the cable is directly attached to an AP: •...
  • Page 58: Connecting To Gigabit Ethernet Devices

    Insert the Cat-5 cable into the port’s RJ-45 (copper) interface. Access the command-line interface (CLI) on the switch, use the enable command to enter configuration mode, and use the following command to set the active interface on the port to...
  • Page 59 For 1000BASE-SX or 1000BASE-LX fiber, make sure you insert the two cable ends in the proper sides (transmit or receive). Otherwise,the link does not work. Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide GBIC Squeeze the lock clips to...
  • Page 60: Connecting To A Fiber Gigabit Device (2382)

    Squeeze the clips on the sides of the GBIC and pull the GBIC out of the slot. Connecting to a Fiber Gigabit Device (2382) You must install a miniature gigabit interface converter (mini-GBIC) to connect an 2382 switch to 1000BASE-SX, 1000BASE-LX, or 1000BASE-TX cable.
  • Page 61 Remove the network cable(s). Insert the protective covering(s) into the port connector(s). Pull the bail latch on the mini-GBIC forward, away from the MX switch, to unlock it from the front panel. Grasping the bail latch, pull the mini-GBIC out of the slot.
  • Page 62 62 Installing and connecting a WSS NN47250-301 (320656-E Version 02.01)
  • Page 63: Wss Technical Specifications

    WSS technical specifications Table 10 Table 11 list the technical specifications for Nortel WLAN—Security Switch (WSS) models 2382 and 2380 respectively. Table 12 lists the technical specifications for model 2360. for model 2350. (For detailed compliance information, consult the regulatory section and the Messages section of this installation guide.
  • Page 64 Table 10. 2382 Mechanical and Compliance Specifications Specification Wired network ports Safety and electromagnetic compliance Table 11. 2380 Mechanical and Compliance Specifications Specification Size Weight Operating Temperature Storage Temperature Humidity NN47250-301 (320656-E Version 02.01) Description • Two miniature gigabit interface converter...
  • Page 65 Specification Size Weight Operating Temperature Storage Temperature Humidity Power supply (each) Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide Description 100-240 ~AC 50 Hz to 60 Hz Up to 350 W at 120 V and 3.5 A at 230 V...
  • Page 66 15.3 W per port maximum Power supply status LEDs Port activity and link speed LEDs (For descriptions of the LEDs, see 2382 LEDs” on page 24.) Six RJ-45 ports for 10/100BASE-T Ethernet and optional Power over Ethernet (PoE) Two RJ-45 ports for 10/100BASE-T Ethernet uplinks...
  • Page 67 Specification Status indicators Wired network ports Safety and electromagnetic compliance Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide Description Power supply status LED Port activity and link speed LEDs Factory reset LED (For descriptions of the LEDs, see page 25.)
  • Page 68 68 WSS technical specifications NN47250-301 (320656-E Version 02.01)
  • Page 69: Wss Troubleshooting

    AP or a radio. Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide Remedy 1. Use set timezone to set the time zone in which you are operating the switch.
  • Page 70 2. Check the authorization rules in the switch’s local database (show aaa) or on the RADIUS servers to ensure the client is authorized to join a VLAN that is configured on at least one of the WSS switches in the Mobility Domain.
  • Page 71: Translations Of Important Messages

    Translations of Important Messages Not all of these warnings apply to every Nortel product. The warnings that apply to a specific product appear in the installation guide for that product. The installation guides containing these warnings are located on the documentation CD.
  • Page 72: Caution Statements

    Caution statements Caution! This device is a Class A product. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense. Attention! Le périphérique est un produit de Classe A.
  • Page 73: Lithium Battery Caution

    Lithium Battery Caution The Nortel Wireless Security Switches contain a lithium battery. If you need to replace the battery, make sure you dispose of the battery properly according to local regulations and replace the battery only with another comparable lithium battery Caution! Risk of explosion if battery is replaced by an incorrect type.
  • Page 74: Warning Conventions

    Warning conventions Warning! This situation or condition can cause injury. Avertissement! Warnung! Diese Situation oder dieser Umstand kann zu Verletzungen führen. Advertencia! Aviso! Esta situação ou condição pode causar ferimentos. Avviso! Situazione o condizione che può causare ferite. Warning! High voltage. This situation or condition can cause injury due to electric shock.
  • Page 75: Qualified Service Personnel Warning

    Leia e siga todos os avisos e instruções destacados no produto ou que façam parte da documentação. Avviso! L'installazione deve essere eseguita esclusivamente da personale qualificato. Leggere e seguire tutti gli avvisi e le istruzioni presenti sul prodotto o inclusi nella documentazione. Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide...
  • Page 76: Laser Warning

    Laser warning Warning! The gigabit Ethernet fiber-optic interfaces use Class 1 lasers. To reduce the risk of eye injury, do not stare into the interface or otherwise direct the laser beam into your eye. Avertissement! produits laser de classe 1. Pour réduire le risque de blessure oculaire, ne regardez pas fixement l'interface ou ne dirigez pas le rayon laser dans votre œil.
  • Page 77: Earth Ground Warning

    Per poter fornire la messa a terra, l'intelaiatura deve essere dotata di una piattina di massa per il collegamento a terra. Le viti metalliche che collegano l'interruttore all'intelaiatura forniscono il collegamento a terra dell'intelaiatura stessa. Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide...
  • Page 78: Overcurrent Warning

    Overcurrent warning Warning! The WSS relies on the building’s installation for overcurrent protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10 A international) is used on the phase conductors. Avertissement! surtension du bâtiment. Assurez-vous de ne pas utiliser un fusible ou un disjoncteur de plus de 120 Vca, 15 A U.S.
  • Page 79: Radio Safety Advisories For Access Points

    WSS. Attenzione! Le radiazioni del dispositivo AP-2330/2330A/2330B and Series 2332 vengono disattivate per impostazione predefinita e possono essere attivate soltanto da un amministratore di sistema tramite WSS. Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide...
  • Page 80 NN47250-300 (320656-E Version 02.01)
  • Page 81: Index

    AP, requirements 46 LEDs 56, 58, 60 network 56 serial console 54 verifying, Ethernet 56 Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration verifying, serial console 55 documentation, product 14 equipment rack installation 48 Ethernet connections, 10/100 Ethernet 56...
  • Page 82 14 model numbers 18 modem settings 54 network cables 45 network connections 56 network plan, WMS 43 Nortel WLAN 2300 Series System 13 NN47250-301 (320656-E Version 02.01) ports Ethernet 23 power supplies 23 installation, 2380 50 LEDs 25...
  • Page 83 WLAN Security Switch. See WSS network plan 43 work order, WMS 43 WSS (WLAN Security Switch) description of 19 front panel 20, 21, 22 model numbers 18 specifications 63 troubleshooting 69 Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide...
  • Page 84 Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Net- works.

This manual is also suitable for:

2350236023612380

Table of Contents