Table 22: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device
Altitude
EX2300
No performance
(except
degradation up to
EX2300-C
13,000 feet
switches)
(3962 meters) at
104° F (40° C) as
per GR-63
EX3200
No performance
degradation up to
10,000 feet
(3048 meters)
EX3300
No performance
degradation up to
10,000 feet
(3048 meters)
EX3400
No performance
degradation up to
10,000 feet
(3048 meters)
EX4200
No performance
degradation up to
10,000 feet
(3048 meters)
Relative Humidity
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Temperature
Normal operation ensured
in the temperature range
32° F (0° C) through 113°
F (45° C)
Normal operation ensured
in the temperature range
32° F (0° C) through 113°
F (45° C)
Normal operation ensured
in the temperature range
32° F (0° C) through 113°
F (45° C)
Normal operation ensured
in the temperature range
32° F (0° C) through 113°
F (45° C)
Normal operation ensured
in the temperature range
32° F (0° C) through 113°
F (45° C)
74
Seismic
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.