SC361 - Incomplete drum potential sensor calibration
Definition: [level: C]
When the process control initial setting is performed and a development
bias of –100 V or –800 V is applied to the drum shaft, the drum potential
voltage is out of these ranges:
0.1 ≤ V–100 ≤ 0.7 [V] or 2.7 ≤ V–800 ≤ 4.2 [V].
Possible causes:
Drum potential sensor defective
Drum shaft terminal not grounded
OPC drum
Main charge corona unit defective
SC364 - Abnormal V
Definition: [level: C]
V
is out of specification (V
D
Possible causes:
Drum potential sensor defective
OPC drum
Main charge corona unit defective
SC365 - Abnormal V
Definition: [level: C]
V
is out of specification (V
L
Possible causes:
Drum potential sensor defective
OPC drum
Main charge corona unit defective
Optics too dirty
SC366
Definition: [level: C]
V
is larger than 360 V in the process control initialization.
R
Possible causes
OPC drum
Drum shaft terminal not ground
detection
D
+ 770 ± 20 V).
R
detection
L
+ 140 ± 20 V).
R
6-11
SERVICE CALL CONDITIONS