RECIRCULATING DOCUMENT HANDLER (A607)
3. Install the cover [A] with a screw (if necessary). The cover and screw are
supplied as an accessory with the copier.
4. Replace the front two screws with M4 shoulder screws [B] and install the
6 mm collar M5 shoulder screws [C] to hook the RDH.
NOTE: There is one screw hole available on the left side for one of the
stepped screw. However there are two screw hole available on
the right where the stepped screw is to be installed.
Install the stepped screw into the outer screw hole [D] as shown
in the illustration.
5. Mount the RDH to the two stepped screws [E] by aligning the holes in the
RDH hinge [F] and the stepped screws, then slide the RDH to the right as
shown.
[B]
A607I502.img
[F]
[A]
[C]
[D]
[E]