15 July 1996
1.2 EXPOSURE
SC101 - Exposure lamp malfunction - abnormal On/Off
Definition: [level: A]
During the lamp off condition, the optics control board detects a lamp
voltage.
Possible causes
Exposure lamp open
Triac shorted
Exposure lamp thermoswitch open
Optics control board defective
SC103 - Power source frequency detection error
Definition: [level: D]
Detects frequencies out of the 45Hz to 65Hz range.
Possible causes:
Abnormal power source
Electrical noise
AC drive board defective
Optics control board defective
SC104 - Exposure lamp malfunction - abnormal off
Definition: [level: D]
The scanner start signal is received even if the main relay off condition is
detected.
Possible causes:
Main relay defective
Communication error between the main control board and the optics
control board because of a poor harness connection.
Optics control board defective
SERVICE CALL CONDITIONS
6-3