SERVICE PROGRAM MODE
2.2 SERVICE PROGRAM MODE TABLE
1
SP ADJUSTMENT
PAGE 1
Item
Both the TD sensor toner supply target
voltage (V
REF
value are set automatically by using new
developer.
Starts the process control data initial
setting.
Increases the period to sufficiently heat
the pressure roller at power on.
Default: 5 min
Adjusts the fusing temperature (1°C/step).
Procedure:
1) Touch
2) Enter the appropriate number by using
the number keys.
3) Press the enter key.
Function
) and the TD sensor gain
.
A176M503.img
With new developer, do not make any
copy before performing the developer
initial setting.
This mode is required when new
developer is installed or the TD sensor is
replaced.
Perform this program when the following
parts have been replaced (or cleaned).
Drum potential sensor/
Exposure lamp/Drum/
Charge corona wire and casing/
Mirrors/Lamps around the drum/
Charge P.P./RAM etc.
Perform this only if poor fusing occurs
just after the power is turned on.
Increase only when thick paper is used
and poor fusing occurs. Default: 185°C
4-8
15 July 1996