17. SPEED CONTROL OPERATION

17.5.5 Point table setting

Set the data for operation to the point table. The following shows the items to be set.

17.5.6 Actual operation

Start actual operation after confirmation of normal operation by test operation and completion of the
corresponding parameter settings.
Item
Not used in speed control operation.
Position data
Do not change the parameter.
Set the command speed of the servo motor for speed control operation.
Servo motor
In the speed control operation, use the servo motor speed of the point table
speed
No.1 to 8.
Set the acceleration time constant.
Acceleration
In the speed control operation, use the acceleration time constant of the point
time constant
table No.1 and 2.
Set the deceleration time constant.
Deceleration
In the speed control operation, use the deceleration time constant of the point
time constant
table No.1 and 2.
Not used in speed control operation.
Dwell
Do not change the parameter.
Not used in speed control operation.
Sub function
Do not change the parameter.