Mitsubishi Electric MELSERVO-J3 Series Instruction Manual page 188

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

5. OPERATION
(2) Indication list
Indication
Status
b # # Waiting for CC-Link
communication
(Note 1) d # # Ready
(Note 1) C # # Not ready
(Note 2) A
Alarm Warning
8
8 8
CPU error
d
0 0.
(Note 3)
C
0 0.
(Note 3)
Test operation mode
d
# #.
(Note 1)
C
# #.
Note 1. ## denotes any of numerals 00 to 16 and what it means is listed below.
2.
indicates the warning/alarm No.
3. Requires MR Configurator or MR-PRU03 parameter module.
Power of the CC-Link master module was switched on at the condition that the power of
CC-Link master module is OFF.
The CC-Link master module is faulty.
The servo was switched on after completion of initialization and the servo amplifier is ready
to operate.
The servo amplifier is being initialized or an alarm has occurred.
The alarm No./warning No. that occurred is displayed. (Refer to section 11.4.)
CPU watchdog error has occurred.
JOG operation positioning operation programmed operation DO forced output single-
step feed
Motor-less operation
##
Description
00
Set to the test operation mode.
01
Station number 1
02
Station number 2
03
Station number 3
:
:
62
Station number 62
63
Station number 63
64
Station number 64
5 - 9
Description
:
:

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents