14. OPTIONS AND AUXILIARY EQUIPMENT
(c) Cable clamp fitting AERSBAN -
Generally, the grounding of the shielded wire may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to a ground plate as shown below.
Install the ground plate near the servo amplifier for the encoder cable. Peel part of the cable sheath to
expose the external conductor, and press that part against the ground plate with the cable clamp. If the
cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the ground plate.
Outline drawing
(Note) M4 screw
Note. Screw hole for grounding. Connect it to the ground plate of the control box.
Type
A
AERSBAN-DSET
100
AERSBAN-ESET
70
SET
Cable
Cable clamp
(A, B)
External conductor
Clamp section diagram
Ground plate
2- 5 hole
17.5
mounting hole
6
22
35
B
C
Accessory fittings
86
30
Clamp A: 2pcs.
56
Clamp B: 1pc.
Strip the cable sheath of
the clamped area.
Ground plate
[Unit: mm]
Clamp Section diagram
L or less
Clamp fitting
A
B
14 - 88
cutter
cable
[Unit: mm]
10
L
70
45
[Unit: mm]