14. OPTIONS AND AUXILIARY EQUIPMENT
(b) 400V class
MCCB
3-phase
380 to
480VAC
(Note 8)
Stepdown
transformer
Note 1. Configure a sequence that will shut off main circuit power at an emergency stop or at FR-CV-H or servo amplifier alarm
occurrence.
2. For the servo motor with thermal sensor, configure a sequence that will shut off main circuit power when the thermal sensor
operates.
3. For the servo amplifier, configure a sequence that will switch the servo on after the FR-CV-H is ready.
4. For the FR-CV-H, the RSO signal turns off when it is put in a ready-to-operate status where the reset signal is input.
Configure a sequence that will make the servo inoperative when the RSO signal is on.
5. Configure a sequence that will make a stop with the emergency stop input of the servo system controller if an alarm occurs
in the FR-CV-H. When the servo system controller does not have an emergency stop input, use the forced stop input of the
servo amplifier to make a stop as shown in the diagram.
6. When using the servo amplifier of 7kW or less, make sure to disconnect the wiring of built-in regenerative resistor (2kW or
less: P-D, 3.5k to 7kW: P-C.
7. When using the servo amplifier of 11k to 22kW, make sure to connect P
8. Stepdown transformer is required for coil voltage of magnetic contactor more than 200V class servo amplifiers.
FR-CVL-H
MC
R2/L
R/L
11
12
S/L
S2/L
21
22
T/L
T2/L
31
32
RESET
(Note 1)
(Note 1)
EMG OFF
RA2 RA3
ON
MC
MC
SK
Servo amplifier
FR-CV-H
L
R2/L
1
L
S2/L
2
(Note 7)
T2/L
3
P/L
N/L
R/L
11
S/L
21
P24
T/MC1
SD
RES
RDYB
(Note 3)
Servo system
SD
RDYA
(Note 4)
RSO
SE
A
RA1
(Note 1)
B
C
24VDC
and P. (Factory-wired.)
1
14 - 59
Servo motor
U
U
11
V
V
21
P
W
W
1
Thermal
P(+)
(Note 6)
CN2
N(-)
EMG
RA1
(Note 5)
(Note 1)
EMG
DOCOM
DICOM
controller
RA2
OHS2
(Note 2)
OHS1