Mitsubishi Electric MELSERVO-J3 Series Instruction Manual page 269

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

6. PARAMETERS
No.
Symbol
PC37 *LPPL Position range output address
Used to set the address increment side position range output address. Set
PC38 *LPPH
the same sign to parameters No.PC37 and PC38. Setting of different signs
will result in a parameter error.
In parameters No.PC37 to PC40, set the range where position range (RXnE)
turns on.
Position range output address
change the value, set in the order of lower digits to upper digits.
PC39 *LNPL Position range output address
Used to set the address decrement side position range output address. Set
PC40 *LNPH
the same sign to parameters No.PC39 and PC40. Setting of different signs
will result in a parameter error.
Position range output address
To change the value, set in the order of lower digits to upper digits.
PC41
For manufacturer setting
PC42
Do not change this value by any means.
PC43
PC44
PC45
PC46
PC47
PC48
PC49
PC50 *COPA Function selection C-A
0 0 0
This parameter is available with servo amplifiers with software version A8
or later.
When this parameter is set using MR Configurator with software version C5
or earlier, the parameter name is not displayed. However, the setting value
is changeable. Follow the instructions in this Instruction Manual to set the
value.
Name and function
Set address:
Upper 3
Lower 3
digits
digits
Parameter No.PC37
Parameter No.PC38
is a set of upper digits and lower digits. To
Set address:
Lower 3
Upper 3
digits
digits
Parameter No.PC39
Parameter No.PC40
is a set of upper digits and lower digits.
CC-Link communication error (A8D)
extended function selection
0: No extended function
1: CC-Link communication error (A8D) detection delay
Use parameter No.PD25 to set how long to delay the
occurrence timing of CC-Link communication error (A8D).
6 - 28
Initial value
Unit
Setting range
STM
0
10
m
m
0
10
STM
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
name and
999999
to
999999
999999
to
999999
Refer to
function
column.