17. SPEED CONTROL OPERATION
Signal name
(Device name)
Speed command execution
completion
Malfunction
Remote station
communication ready
Refer to speed command execution demand (RY(n+2)1).
Malfunction is assigned to the CN6-15 pin as an external output signal.
RX(n+1)A or RX(n+3)A turns on when the protective circuit is activated to shut
off the base circuit. When no alarm has occurred, RX(n+1)A or RX(n+3)A turns
off within about 1.5 s after power is switched on.
This signal turns on at power-on and turns off at an alarm occurrence or in the
reset (RY(n+1)A or RY(n+3)A) on status.
Description
17 - 10
Device No.
1 station
2 stations
occupied
occupied
RX(n+2)1
RX(n+1)A RX(n+3)A
RX(n+1)B RX(n+3)B