17. SPEED CONTROL OPERATION
No.
Symbol
PB14
NHQ1
Notch shape selection 1
Select the shape of the machine resonance suppression filter 1.
Setting parameter No.PB01 (adaptive tuning mode) to "
automatically changes this parameter.
When the parameter No.PB01 setting is "
parameter is ignored.
PB15
NH2
Machine resonance suppression filter 2
Set the notch frequency of the machine resonance suppression filter 2.
Set parameter No.PB16 (Notch shape selection 2) to "
parameter.
PB16
NHQ2
Notch shape selection 2
Select the shape of the machine resonance suppression filter 2.
PB17
Automatic setting parameter
The value of this parameter is automatically set according to the set value of
parameter No.PB06 (Load to motor inertia ratio).
Name and function
0
0
Notch depth selection
Setting
0
1
2
3
Notch width selection
Setting
0
1
2
3
0
Machine resonance suppression filter 2 selection
0: Invalid
1: Valid
Notch depth selection
Setting
0
1
2
3
Notch width selection
Setting
0
1
2
3
Depth
Gain
Deep
-40dB
-14dB
to
-8dB
Shallow
-4dB
Width
Standard
2
3
to
4
Wide
5
1"
0", the setting of this
1" to enable this
Depth
Gain
Deep
-40dB
-14dB
to
-8dB
Shallow
-4dB
Width
Standard
2
3
to
4
Wide
5
17 - 46
Initial
Setting
Unit
value
Range
0000h
Refer to
the Name
and
function
column.
4500
Hz
100
to
4500
0000h
Refer to
the Name
and
function
column.

Hide quick links: