Retry Processing; Initialization - Mitsubishi Electric MELSERVO-J3 Series Instruction Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

15. COMMUNICATION FUNCTION

15.3.6 Retry processing

When a fault occurs in communication between the master and slave stations, the error code in the response
data from the slave station is a negative response code ([B] to [F], [b] to [f]). In this case, the master station
retransmits the message which was sent at the occurrence of the fault. A communication error occurs if the
above processing is repeated and results in the error three or more consecutive times.
Controller
(Master station)
Servo
(Slave station)
Similarly, when the master station detects a fault (e.g. checksum, parity) in the response data from the slave
station, the master station retransmits the message which was sent at the occurrence of the fault. A
communication error occurs if the retry processing is performed three times.

15.3.7 Initialization

After the slave station is switched on, it cannot reply to communication until the internal initialization processing
terminates. Hence, at power-on, ordinary communication should be started after.
(1) 1s or more time has elapsed after the slave station is switched on; and
(2) Making sure that normal communication can be made by reading the parameter or other data which does
not pose any safety problems.
S
T
X
Station number
or
group
S
T
X
Station number
or
group
15 - 8
*Communication error
S
T
X
Station number
or
group

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents