17. SPEED CONTROL OPERATION
17.8.3 Extension setting parameters (No.PC
(1) Parameter list
No.
PC01
PC02
PC03
PC04
PC05
PC06
PC07
PC08
PC09
PC10
PC11
PC12
PC13
PC14
PC15
PC16
PC17
PC18
PC19
PC20
PC21
PC22
PC23
PC24
PC25
PC26
PC27
PC28
PC29
PC30
PC31
PC32
PC33
PC34
PC35
PC36
PC37
PC38
PC39
PC40
PC41
PC42
Symbol
For manufacturer setting
Not used in speed control operation.
Do not change the parameter.
*STC
S-pattern acceleration/deceleration time constant
Not used in speed control operation.
Do not change the parameter.
For manufacturer setting
MBR
Electromagnetic brake sequence output
ZSP
Zero speed
*BPS
Alarm history clear
*ENRS Encoder output pulse selection
*SNO
Station number setting
*SOP
RS-422 communication function selection
*COP1 Function selection C-1
For manufacturer setting
Not used in speed control operation.
Do not change the parameter.
For manufacturer setting
*COP5 Function selection C-5
For manufacturer setting
Not used in speed control operation.
Do not change the parameter.
For manufacturer setting
*DSS
Remote register-based speed specifying method selection
Not used in speed control operation.
Do not change the parameter.
TL2
Internal torque limit 2
For manufacturer setting
Not used in speed control operation.
Do not change the parameter.
For manufacturer setting
)
Name and function
17 - 49
Initial
Unit
value
0000h
0000h
0001h
500
10
0
0
1000
100
15.0
0
100
0
ms
0
0000h
100
ms
50
r/min
0000h
0000h
0
station
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0
0
100.0
%
0000h
0
0
0000h
0000h

Hide quick links: