6. PARAMETERS

6.1.7 Feeding function selection

No.
Symbol
PA05
*FTY
Feeding function selection
Select the feed length multiplication, the manual pulse generator input multiplication, and the servo motor
speed setting unit.
Parameter No.PA05
0

6.1.8 Electronic gear

No.
Symbol
PA06
*CMX
Electronic gear numerator
PA07
*CDV
Electronic gear denominator
CAUTION
Parameter
Name
POINT
This parameter is made valid when power is switched off, then on after
setting.
Feed length
Setting
multiplication
value
factor (STM)
[times]
0
1
1
10
2
100
3
1000
Manual pulse generator multiplication factor
0: 1 time
1: 10 times
2: 100 times
Servo motor speed setting unit selection
0: 1r/min unit
1: 0.1r/min unit
Setting to "1" will be as follows.
The setting value of the servo motor speed will be limited to 6553.5r/min.
The "Servo motor speed" status will be displayed as 0.1r/min unit.
Setting of this digit is available with servo amplifiers with software version A4 or later.
Parameter
Name
False setting will result in unexpected fast rotation, causing injury.
POINT
This parameter is made valid when power is switched off, then on after
setting.
The range of the electronic gear setting is
value outside this range, a parameter error (A37) occurs.
Setting "0" in parameter No.PA06 automatically sets the encoder resolution
pulse.
Feed unit
Absolute value
[ m]
command system
1
-999.999 to +999.999
10
-9999.99 to +9999.99
100
-99999.9 to +99999.9
1000
-999999 to +999999
1
10
6 - 6
Initial
Unit
Setting range
value
0000h
Refer to the text.
Position data input range [mm]
Incremental value
command system
0 to +999.999
0 to +9999.99
0 to +99999.9
0 to +999999
Initial
Unit
Setting range
value
1
0 to 65535
1
1 to 65535
CMX
2000 . If you set any
CDV

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents