17. SPEED CONTROL OPERATION
Signal name
(Device name)
Monitor output execution
demand
Instruction code execution
demand
Speed selection 1
Speed selection 2
Speed selection 3
Speed acceleration /
deceleration selection
Speed command execution
demand
When RYn8 is turned on, the following data and signals are set. At the
same time, RXn8 turns on. While RYn8 is on, the monitor values are
kept updated.
1) When 1 station is occupied
Remote register RW
: Data requested by Monitor 1 (RW
rn
Remote register RW
+1: Data requested by Monitor 2 (RW
rn
Remote register RW
+2: Respond code indicating normal or error
rn
2) When 2 stations are occupied
Remote register RW
: Lower 16 bits of data demanded by Monitor
rn
1(RW
Remote register RW
+1: Upper 16 bits of data demanded by
rn
Remote register RW
+5: Lower 16 bits of data demanded by
rn
Remote register RW
+6: Upper 16 bits of data demanded by
rn
Remote register RW
+2: Respond code indicating normal or error
rn
When RYn9 is turned on, process corresponding to the instruction
code set to the remote register RW
After completion of instruction code execution, the respond code
indicating normal or error is set to RW
turns on.
Refer to section 17.2.4 for details of instruction code.
Select the servo motor speed in the point table No.1 to 8 using RYnA
to RYnC.
You can also switch the servo motor speed during operation.
Point table No.
1
2
3
4
5
6
7
8
Note. 0:OFF
1:ON
When RYnD is turned off, acceleration and deceleration time constant
set in the point table No.1 will be selected.
When RYnD is turned on, acceleration and deceleration time constant
set in the point table No.2 will be selected.
When RY(n+2)1 is turned on, the point table No. or speed command
data set in remote register RW
When it is set to the servo amplifier, the respond code indicating
normal or error is set to RW
+2. At the same time, Speed command
rn
execution completion (RX(n+2)1) turns on.
By setting parameter No.PC50, you can choose the timing when the
speed command data of remote register is reflected.
Refer to section 17.7.2 for details.
Description
)
wn
Monitor
1(RW
)
wn
Monitor
2(RW
+2)
wn
Monitor
2(RW
+2)
wn
+2 will be executed.
wn
+2. At the same time, RXn9
rn
(Note) RY of CC-Link
RYnC
RYnB
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
+6 is set.
wn
17 - 7
Device No.
1 station
2 stations
occupied
occupied
RYn8
RYn8
)
wn
+1)
wn
RYn9
RYn9
RYnA
RYnA
RYnB
RYnB
RYnA
RYnC
RYnC
0
1
0
1
0
1
0
1
RYnD
RYnD
RY(n+2)1
Remarks
*3
*3