14. OPTIONS AND AUXILIARY EQUIPMENT
(3) Connection diagram
(a) 200V class
MCCB
3-phase
200 to
230VAC
RA2 RA3
Note 1. Configure a sequence that will shut off main circuit power at an emergency stop or at FR-CV or servo amplifier alarm
occurrence.
2. For the servo motor with thermal sensor, configure a sequence that will shut off main circuit power when the thermal sensor
operates.
3. For the servo amplifier, configure a sequence that will switch the servo on after the FR-CV is ready.
4. For the FR-CV, the RSO signal turns off when it is put in a ready-to-operate status where the reset signal is input.
Configure a sequence that will make the servo inoperative when the RSO signal is on.
5. Configure a sequence that will make a stop with the emergency stop input of the programmable controller if an alarm occurs
in the FR-CV. When the programmable controller does not have an emergency stop input, use the forced stop input of the
servo amplifier to make a stop as shown in the diagram.
6. When using the servo amplifier of 7kW or less, make sure to disconnect the wiring of built-in regeneration resistor (3.5kW or
less: P-D, 5k/7kW: P-C).
7. When using the servo amplifier of 11k to 22kW, make sure to connect P
FR-CVL
MC
R/L
R2/L
11
12
S/L
S2/L
21
22
T/L
T2/L
31
32
RESET
(Note 1)
(Note 1)
EMG OFF
ON
MC
MC
SK
Servo amplifier
FR-CV
L
R2/L
1
L
S2/L
2
(Note 7)
P
T2/L
3
P/L
P
(Note 6)
N
N/L
R/L
11
S/L
21
P24
T/MC1
SD
RES
RDYB
(Note 3)
Servo system
SD
RDYA
(Note 4)
RSO
SE
A
(Note 1)
RA1
B
C
24VDC
and P. (Factory-wired.)
1
14 - 58
Servo motor
U
U
11
V
V
21
W
W
1
Thermal
CN2
EMG
RA1
(Note 1)
(Note 5)
EMG
DOCOM
DICOM
controller
RA2
0HS2
(Note 2)
0HS1