1. FUNCTIONS AND CONFIGURATION
Servo amplifier
MR-J3-
Item
Dog type
Count type
Data setting type
Stopper type
Home position
ignorance
(Servo-on position
as home position)
Dog type rear end
Home
reference
position
return
mode
Count type front
end reference
Dog cradle type
Dog type last
Z-phase reference
Dog type front end
reference
Dogless
Z-phase reference
Automatic positioning to home
position
Other functions
Close mounting (Note 2)
Structure
10T 20T 40T 60T 70T 100T 200TN 350T 500T 700T 11KT 15KT 22KT 10T1 20T1 40T1
Home position return is made starting with Z-phase pulse after passage of proximity dog.
Home position address may be set. Home position shift distance may be set. Home position return
direction may be selected.
Automatic retract on dog back to home position/automatic stroke retract function.
Home position return is made by counting encoder pulses after contact with proximity dog.
Home position address may be set. Home position shift value may be set. Home position return
direction may be set.
Automatic retract on dog back to home position/automatic stroke retract function.
Home position return is made without dog.
Home position may be set at any position by manual operation, etc. Home position address may be
set.
Home position return is made by pressing machine part against stroke end.
Home position address may be set. Home position return direction may be set.
Position where servo-on (RYn0) is switched on is defined as home position.
Home position address may be set.
Home position return is made with respect to the rear end of a proximity dog.
Home position address may be set. Home position shift value may be set. Home position return
direction may be set.
Automatic retract on dog back to home position/automatic stroke retract function.
Home position return is made with respect to the front end of a proximity dog.
Home position address may be set. Home position shift value may be set. Home position return
direction may be set.
Automatic retract on dog back to home position/automatic stroke retract function.
Home position return is made with respect to the front end of a proximity dog by the first Z-phase
pulse.
Home position address may be set. Home position shift value may be set. Home position return
direction may be set.
Automatic retract on dog back to home position/automatic stroke retract function.
Home position return is made with respect to the front end of a proximity dog by the last Z-phase
pulse.
Home position address may be set. Home position shift value may be set. Home position return
direction may be set.
Automatic retract on dog back to home position/automatic stroke retract function.
Home position return is made to the dog front end with respect to the front end of a proximity dog.
Home position address may be set. Home position shift value may be set. Home position return
direction may be set.
Automatic retract on dog back to home position/automatic stroke retract function.
Home position return is made with respect to the first Z-phase to the Z-phase.
Home position address may be set. Home position shift value may be set. Home position return
direction may be set.
High-speed automatic return to a defined home position.
Absolute position detection, backlash function
Overtravel prevention using external limit switch
Software stroke limit
Natural-cooling,
open
(IP rating: IP00)
1 - 8
Force-cooling, open
(IP rating: IP00)
Natural-cooling,
Open
(IP rating: IP00)

Hide quick links: