APPENDIX
(2) Installation
The MR-J3 series have been approved as the products which have been installed in a control box. The
minimum control box size is based on 150% of each unit combination. And also, design the control box so
that the ambient temperature in the control box is 55
The servo amplifier must be installed in a metal control box.
(3) Short circuit rating (SCCR: Short Circuit Current Rating)
Suitable For Use In A Circuit Capable Of Delivering Not More Than 100 kA rms Symmetrical Amperes, 500
Volts Maximum.
(4) Flange
Mount the servo motor on a flange which has the following size or produces an equivalent or higher heat
dissipation effect.
Flange size
HF-MP
[mm]
HF-KP
053 13 2
250 250 6
3
250 250 12
43
300 300 12
73
300 300 20
550 550 30
650 650 35
950 950 35
(5) Capacitor discharge time
The capacitor discharge time is as follows. To ensure safety, do not touch the charging section for 15
minutes after power-off.
Servo amplifier
MR-J3-10T 20T
MR-J3-40T 60T(4)
MR-J3-70T
MR-J3-40T1
MR-J3-100T(4)
HF-SP
HC-RP
51 81
52(4) to
103 to 203
152(4)
121 201
202(4) to
352(4)
353 503
301 421
502(4) to
702(4)
Discharge time
[min]
1
10T1 20T1
2
3
4
5
App. - 32
(131°F) or less.
Servo motor
HC-UP
HC-LP
52 to 152
202 302
72 152
701M(4) to 15K1M(4) 502 to
202 to 502
Servo amplifier
MR-J3-200TN 200T4 350T
MR-J3-350T4 500T(4)
MR-J3-11KT(4)
MR-J3-15KT(4)
MR-J3-22KT(4)
HA-LP
53 to 203
534 to 2034
353 to 503
3534 to 5034
601(4) to 12K1(4)
11K1M
22K2
11K1M
11K24 to 22K24
15K1(4) to 37K1(4)
22K1M 22K1M4
Discharge time
700T(4)
HF-JP
15K1M
15K1M
[min]
9
10
4
6
8

Hide quick links: