3. CC-LINK COMMUNICATION FUNCTIONS
Code No.
Acceleration time constant data EEP-ROM
8E01h
command of point table
to
Writes the acceleration time constants of point
8EFFh
table No.1 to 255 to EEP-ROM. Written to
EEP-ROM, these values are held if power is
switched off.
The decimal value converted from the 2 lower
digits of the code No. corresponds to the point
table No.
Deceleration time constant data EEP-ROM
8F01h
command of point table
to
Writes the deceleration time constants of
8FFFh
point table No.1 to 255 to EEP-ROM. Written
to EEP-ROM, these values are held if power
is switched off.
The decimal value converted from the 2 lower
digits of the code No. corresponds to the point
table No.
Dwell data EEP-ROM command of point table
9001h
Writes the dwell data of point table No.1 to
to
255 to EEP-ROM. Written to EEP-ROM,
90FFh
these values are held if power is switched off.
The decimal value converted from the 2 lower
digits of the code No. corresponds to the point
table No.
Auxiliary function data EEP-ROM command
9101h
of point table
to
Writes the auxiliary function data of point table
91FFh
No.1 to 255 to EEP-ROM. Written to EEP-
ROM, these values are held if power is
switched off.
The decimal value converted from the 2 lower
digits of the code No. corresponds to the point
table No.
Item
Convert the values into hexadecimal before setting.
Convert the values into hexadecimal before setting.
Convert the values into hexadecimal before setting.
Convert the values into hexadecimal before setting.
3 - 30
Writing data (RWwn+3) contents
(Programmable controller
Servo amplifier)