Check Active Alarms With The J-Web Interface - Juniper QFX5110 Series Hardware Documentation

Virtual chassis fabric
Hide thumbs Also See for QFX5110 Series:
Table of Contents

Advertisement

Check Active Alarms with the J-Web Interface

Purpose
NOTE:
This topic applies only to the J-Web Application package.
Use the monitoring functionality to view alarm information for the EX Series switches including alarm type,
alarm severity, and a brief description for each active alarm on the switching platform.
Action
To view the active alarms:
1. Select Monitor > Events and Alarms > View Alarms in the J-Web interface.
2. Select an alarm filter based on alarm type, severity, description, and date range.
3. Click Go.
All the alarms matching the filter are displayed.
NOTE:
When the switch is reset, the active alarms are displayed.
Meaning
Table 136 on page 639
lists the alarm output fields.
Table 136: Summary of Key Alarm Output Fields
Field
Values
Type
Category of the alarm:
Severity
Alarm severity—either major (red) or minor (yellow or amber).
Description
Brief synopsis of the alarm.
Time
Date and time when the failure was detected.
Chassis—Indicates an alarm condition on the chassis (typically an environmental alarm such
as one related to temperature).
System—Indicates an alarm condition in the system.
639