Environmental Requirements And Specifications For A Qfx5100 Device - Juniper QFX5110 Series Hardware Documentation

Virtual chassis fabric
Hide thumbs Also See for QFX5110 Series:
Table of Contents

Advertisement

Table 17: QFX5110 Environmental Tolerances
Description
Altitude
Relative humidity
Temperature
Seismic
NOTE:
Install QFX Series devices only in restricted areas, such as dedicated equipment rooms
and equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National
Electrical Code, ANSI/NFPA 70.
RELATED DOCUMENTATION
QFX5110 Clearance Requirements for Airflow and Hardware Maintenance | 121
Standalone Installation Overview | 262

Environmental Requirements and Specifications for a QFX5100 Device

The switch must be installed in a rack or cabinet. It must be housed in a dry, clean, well-ventilated, and
temperature-controlled environment.
Tolerance
No performance degradation to 6562 feet (2000 meters)
Normal operation ensured in relative humidity range of 5% through 90%,
noncondensing
Short-term operation ensured in relative humidity range of 5% through
93%, noncondensing
NOTE:
As defined in NEBS GR-63-CORE, Issue 3, short-term events can
be up to 96 hours in duration but not more than 15 days per year.
Normal operation ensured in temperature range of 32° F through 104° F
(0° C through 40° C)
Nonoperating storage temperature in shipping container: –40° F through
158° F (–40° C through 70° C)
Designed to comply with Zone 4 earthquake requirements per NEBS
GR-63-CORE, Issue 3.
99