CHAPTER 31

Replacing QFX5100 Components

IN THIS CHAPTER

Installing and Removing QFX5100 Device Hardware Components

The QFX5100 switch chassis is a rigid sheet-metal structure that houses the hardware components. The
field-replaceable units (FRUs) in QFX5100 devices are:
Power supply
Fan module
Expansion module (QFX5100-24Q and QFX5100-24Q-AA only)
SFP+ transceiver
QSFP+ transceiver
All of the QFX5100 device FRUs are hot-insertable and hot-removable: you can remove and replace them
without powering off the switch or disrupting switch functions.
CAUTION:
of removal to prevent chassis overheating. Replace a failed fan module with a new fan
within 1 minute of removal to prevent chassis overheating.
Replace a failed power supply with a new power supply within 1 minute