Cabling A Virtual Chassis Fabric; Connecting Qfx5110 In A Qfx5110 Virtual Chassis Fabric - Juniper QFX5110 Series Hardware Documentation

Virtual chassis fabric
Hide thumbs Also See for QFX5110 Series:
Table of Contents

Advertisement

CHAPTER 28

Cabling a Virtual Chassis Fabric

IN THIS CHAPTER

Connecting QFX5110 in a QFX5110 Virtual Chassis Fabric | 385

Connecting a QFX5100 Device in a Virtual Chassis Fabric | 387
Connecting a QFX3500 or QFX3600 Switch in a QFX5100 Virtual Chassis Fabric | 389
Connecting EX Series Switches in a QFX5100 Virtual Chassis Fabric | 391
Connecting QFX5110 in a QFX5110 Virtual Chassis Fabric
A Juniper Networks QFX5110 Virtual Chassis Fabric (VCF) is constructed using a spine-and-leaf architecture
and topology. In the spine-and-leaf architecture, each spine device is interconnected to each leaf device.
QFX5110 VCFs support a maximum of 20 members in a VCF. Use QFX5110-32Q as either the spine or
as a leaf device. Use QFX5110-48S, QFX5100-24Q, QFX5100-48S, QFX5100-48T, or QFX5100-96S
models only as leaf devices.
Figure 81 on page 296
shows cabling for a QFX5110 VCF with two QFX5110-32Q spine devices connected
to four QFX5110-48S as leaf devices, all using all QSFP28 ports as
the cabling for a QFX5110 VCF using QFX5110-32Q as spines and QFX5100-24Q leaf devices.
VCPs.Figure 131 on page 386
385
shows