Dc Power Supply Leds On A Qfx3500, Qfx3600, Or Qfx3600-I Device - Juniper QFX5110 Series Hardware Documentation

Virtual chassis fabric
Hide thumbs Also See for QFX5110 Series:
Table of Contents

Advertisement

Table 101: AC Power Supply LEDs on a QFX3500, QFX3600, or QFX3600-I Device
LED
Color
AC OK
Unlit
Green
DC OK
Unlit
Green
Fault
Amber
NOTE:
If the AC OK LED and the DC OK LED are unlit, either the AC power cord is not installed
properly or the power supply fuse has failed. If the AC OK LED is lit and the DC OK LED is unlit,
the AC power supply is installed properly, but the power supply has an internal failure.
RELATED DOCUMENTATION
AC Power Supply for a QFX3500, QFX3600, or QFX3600-I Device
Connecting AC Power to a QFX3500, QFX3600, or QFX3600-I Device | 309

DC Power Supply LEDs on a QFX3500, QFX3600, or QFX3600-I Device

Figure 196 on page 525
State
Description
Off
The power supply is disconnected from power, or power is not
coming into the power supply.
On steadily
Power is coming into the power supply.
Off
The power supply is disconnected from power, or the power supply
is not sending out power correctly.
On steadily
The power supply is sending out power correctly.
On steadily
An error has been detected in the power supply. Replace the power
supply as soon as possible. To maintain proper airflow through the
chassis, leave the power supply installed in the chassis until you
are ready to replace it.
shows the location of the LEDs on the DC power supply.