Table 29: Cabinet Requirements for the QFX3500 Device (continued)
Cabinet
Requirement
Guidelines
Cabinet airflow
When you mount the device in a cabinet, ensure that ventilation through the cabinet is
requirements
sufficient to prevent overheating.
RELATED DOCUMENTATION
Clearance Requirements for Airflow and Hardware Maintenance for a QFX3500 Device | 125
Rack Requirements for a QFX3500 Device | 114
Mounting a QFX3500 Device in a Rack or Cabinet | 328

Cabinet Requirements

You can mount the device in a cabinet that contains a 19-in. rack.
Cabinet requirements consist of:
Cabinet size
Clearance requirements
Cabinet airflow requirements
Table 30 on page 121
provides the cabinet requirements and specifications.
Ensure that the cool air supply you provide through the cabinet adequately dissipates the
thermal output of the device (or devices).
Ensure that the cabinet allows the chassis hot exhaust air to exit the cabinet without
recirculating into the device. An open cabinet (without a top or doors) that employs hot air
exhaust extraction from the top allows the best airflow through the chassis. If the cabinet
contains a top or doors, perforations in these elements assist with removing the hot air
exhaust.
The device fans exhaust hot air through the rear of the chassis. Install the device in the
cabinet in a way that maximizes the open space on the fan tray side of the chassis. This
maximizes the clearance for critical airflow.
Route and dress all cables to minimize the blockage of airflow to and from the chassis.
Ensure that the spacing of rails and adjacent cabinets allows for the proper clearance around
the device and cabinet.