Operation Indicators For System Errors - Omron V780 Series User Manual

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

Operation Indicators during Single-access Communications for
Reception Level Monitoring
The NORM/ERR indicators will flash according to the reception power of the RF Tag during sin-
gle-access communications testing for the Reception Level Monitor of the Web browser interface.
The RUN indicator lights cyan.
The LINK/ACT indicator does not light.
The NORM/ERR indicators flash green
at 0.4-s intervals.
NORM/ERR: Green
3-1-8

Operation Indicators for System Errors

Minor Faults
If a minor fault is detected, the NORM/ERR indicators will flash red at 0.4-second intervals.
To recover normal operation, initialize the Reader/Writer settings and then restart the Reader/Writer.
However, if an illegal network setting or an incorrect operating mode is detected during operation, the
RUN indicator will flash red and the Reader/Writer will start in Safe Mode.
The RUN indicator lights green.
The NORM/ERR indicators flash red
at 0.4-s intervals.
NORM/ERR: Red
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
3 Part Names and Functions
RUN: Cyan
LINK/ACT: Not lit.
NORM/ERR: Green
NORM/ERR: Green
NORM/ERR: Green
RUN: Green
NORM/ERR: Red
NORM/ERR: Red
NORM/ERR: Red
3
3 - 9