 Saving Files
You can click the Save Button on the RF Communications Diagnostics Log Tab Page to save the RF
communications diagnostics log at a specified path and file name. The RF communications diagnostics
log information is saved in a CSV file in the following format.
CSV Format
No, Time, Command, Result, Diagnostics result, Diagnostic details, Reception level[dBm], Noise level[dBm], UII (EPC)
1 <time>, <command_name>,<RF_communications_result>,<diagnostic_result>,<diagnostic_details>,<reception_level>,<noise_level>,<UII (EPC code)>
2
:
Total, XX
Warning, YY
Error, ZZ
Item name
No
Time
Command
Result
Diagnostics result
Diagnostic details
Reception level[dBm] Gives the reception level measured during communications diagnostics.
Noise level[dBm]
Channel
RF communications
speed
Target level
UII (EPC)
Total
Error
Warning
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
:
:
Gives the log record number.
1 to 8192
Gives the time when the Reader/Writer executed the RF communica-
tions command.
hh:mm:ss
hh: hour, mm: minutes, ss: seconds (second increments)
Gives the name of the command that was executed by the
Reader/Writer.
"Command name text"
Gives the execution result for the RF communications command.
Normal: Normal communications
Warning: Unstable communications
Error: Communications error
Gives the communications diagnostic results.
Normal
Insufficient power to send
Insufficient power to receive
Too much noise
Insufficient read data
Excessive read data
Error name text: RF Tag communications error name
Gives all diagnostic results detection status as bit information in four
hexadecimal digits.
XXXX hex
0 or -1 to -99
Gives the noise level measured during communications diagnostics.
0 or -1 to -99
Displays the channel that the Reader/Writer communicated with the RF
Tag.
Displays the communications speed that the Reader/Writer communi-
cated with the RF Tag.
Displays the target level measured during communications diagnostics.
Gives the UIIs (EPC codes) of the RF Tags that were detected during RF
communications diagnostics in hexadecimal.
XX ... XX hex
Gives the total number of log records in decimal.
Gives the number of communications errors in the log in decimal.
Gives the number of unstable communications in the log in decimal.