7 Modbus/TCP Communications
SET ACCESS PASSWORD
 Function
This command sets the access password for RF Tag communications of the Reader/Writer.
 Command Format
Byte-0
Byte-1
Transaction identi-
fier
X
X
Byte-12
Byte-13
Byte
Access password
count
04 hex
Parameter
Register address
Access password
 Response Formats
• Normal Response
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Word count
• Error Response
Byte-0
Byte-1
Transaction identifier
X
X
Parameter
Exception code
7 - 88
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
000B hex
...
Byte-16
4 bytes
The register address (C400 hex) that specifies the access password setting
Specify the access password to use for RF Tag communications in
8-digit hexadecimal.
The specified access password is stored in EEPROM memory in
the Reader/Writer.
If the access password in the RF Tag is not all zeros, the access
password that is stored in EEPROM memory must be used to exe-
cute LOCK, ID WRITE, DATA READ, or DATA WRITE commands.
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
0006 hex
Always 0002 hex.
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0003 hex
For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for
Error Completion on page 7-7.
Byte-6
Byte-7
Byte-8
Unit
Function
Register address
identifier
code
FF hex
10 hex
Description
Byte-6
Byte-7
Byte-8
Unit
Function
Register address
identifier
code
FF hex
10 hex
Description
Byte-5
Byte-6
Byte-7
Unit iden-
Function
tifier
code
FF hex
90 hex
Description
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-9
Byte-10
Byte-11
Word count
C400 hex
0002 hex
Default setting
00000000 hex
Byte-9
Byte-10
Byte-11
Word count
C400 hex
0002 hex
Byte-8
Excep-
tion code
1 byte