Omron V780 Series User Manual page 169

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

Host device
(client)
SET MULTIACCESS DATA READ
communications command sent.
Response returned.
GET MULTIACCESS DATA READ RESULTS communications command sent.
Response returned.
Number of RF Tags: 3
Error code
GET MULTIACCESS DATA READ RESULTS communications command sent.
Response returned.
Number of RF Tags: 2
Error code
GET MULTIACCESS DATA READ RESULTS communications command sent.
Response returned.
Number of RF Tags: 1
Error code
Precautions for Correct Use
If you execute another communications command (e.g., a single-access read, write, or fill com-
mand or a multiaccess read command) before you execute the commands to get the results,
the multiaccess communications results held in the Reader/Writer will be cleared.
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Reader/Writer
(server)
Timeout (TMO)
RF Tag A
communications
UII (EPC code)
Read data
results
+ Reception level
RF Tag B
communications
UII (EPC code)
Read data
results
+ Reception level
RF Tag C
communications
UII (EPC code)
Read data
results
+ Reception level
7 Modbus/TCP Communications
Communications range
RF Tag memory
read/written.
RF Tag A
RF Tag B
RF Tag C
7
7 - 17