7 Modbus/TCP Communications
 Response Formats
• Normal Response
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Register address
Word count
• Error Response
Byte-0
Byte-1
Transaction identifier
X
X
Parameter
Exception code
 Execution Examples
Example 1: Execution to Set the Following Times in the Reader/Writer
<Stop time: 10 ms (000A hex), Continuous transmission time: 400 ms (0190 hex)>
TX: 00000000000BFF10C700000204000A0190
RX: 000000000006FF10C7000002
Example 2: Execution to Set the Following Times in the Reader/Writer
<Stop time: None, Continuous transmission time: Infinite>
TX: 00000000000BFF10C70000020400000000
RX: 000000000006FF10C7000002
7 - 100
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
0006 hex
The register address from the command is set.
The word count from the command is set.
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0003 hex
For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for
Error Completion on page 7-7.
Byte-6
Byte-7
Byte-8
Unit
Function
Register address
identifier
code
FF hex
10 hex
Description
Byte-5
Byte-6
Byte-7
Unit iden-
Function
tifier
code
FF hex
90 hex
Description
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-9
Byte-10
Byte-11
Word count
C700 hex
0002 hex
Byte-8
Excep-
tion code
1 byte

Advertisement