Omron V780 Series User Manual page 235

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

GET CHANNEL
 Function
This command writes the ID (i.e., the UII (EPC code)) to the RF Tag in the communications range.
 Command Format
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Register address Register address (C200 hex) that specifies the channel
Word count
 Response Formats
• Normal Response
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Field Length
Byte count
*1
Channel
V780-HMD68-ETN-JP
V780-HMD68-ETN-IN
V780-HMD68-ETN-EU
V780-HMD68-ETN-RU
*1. You can specify only the channels used in the model V780-HMD68-ETN-JP/-IN/-EU/-RU. You cannot specify
the channel in other models.
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0006 hex
Description
0001 hex (Fixed)
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
0005 hex
0005 hex (Fixed)
02 hex (Fixed)
Specify the channel in 4-digit hexadecimal.
0000 hex: Automatic
0005 hex: 5CH
000B hex: 11CH
0011 hex: 17CH
0000 hex: Automatic
0004 hex: 4CH
0007 hex: 7CH
000A hex: 10CH
0000 hex: Automatic
0004 hex: 4CH
0007 hex: 7CH
000A hex: 10CH
000D hex: 13CH
0000 hex: Automatic
0007 hex: 7CH
000A hex: 10CH
000D hex: 13CH
7 Modbus/TCP Communications
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
03 hex
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
03 hex
Description
Byte-8
Byte-9
Byte-10
Byte-11
Register address
Word count
C200 hex
1 byte
Byte-8
Byte-9
Byte-10
Byte
Channel
count
02 hex
2 bytes
Default setting
0000 hex
7
7 - 83

Advertisement

Table of Contents
loading